  • Do I need an elevator? - The Building Code Forum
    We have a client who is interested in exploring the possibility of adding a mezzanine or second floor level above an existing area in a large multi-story assembly building The area we would be working on is 3,088 square feet While there are existing elevators in the building, they wouldn't be
  • mezzanine | Building Code Forum: Construction Compliance
    MEZZANINE USED ONLY FOR STORAGE A building that I am working on has an existing mezzanine that was permitted The mezzanine is used only for storage The existing common path of travel exceeds 100' Are there any exceptions in the code that allow the common path of travel to be disregarded for storage mezzanines? I
  • Mezzanine | Building Code Forum: Construction Compliance
    A mezzanine shall be open and unobstructed to the room in which such mezzanine is located except for walls not more than 42 inches (1067 mm) in height, columns and posts
  • Is a Mezzanine considered a floor? - The Building Code Forum
    The mezzanine is a "floor" and the level of exit discharge is at the floor level below (even though the mezzanine is part of that story) ClassicT provided one interpretation that is possible and I've provided another interpretation that is possible--this is just an extremely gray area of the code
  • Mezzanine vs. 2nd floor - The Building Code Forum
    As proposed, the mezzanine story sits above the B-range and extends out and over the M-retail space, and would be used as offices in support of the operation and accessory storage Without going too far into the weeds, the mezzanine story will be constructed within the existing attic, incorporating the widely spaced trusses into the space plans
  • Mezzanine Question - The Building Code Forum
    I am only allowed two stories but have 26' total height to play with and am thinking about incorporating a mezzanine into our design Am I allowed to build underneath the mezzanine I would like to put a closet and bathroom under the mezzanine Would that be allowed?
  • Mezzanine Size Calculation | Building Code Forum: Construction Compliance
    MEZZANINE An intermediate level or levels between the floor and ceiling of any story The first question, then, is whether your mezzanine is, in fact, a mezzanine? Is it actually an intermediate level between the floor and ceiling of a story? Then there's the issue of the allowable size Mezzanines are addressed in section R325 of the IRC
  • Mezzanine - Accessible Means of Egress vs. Accessible Route
    Mezzanine will be served by a single, unenclosed stairway CPET exit distance from most remote corner of mezz to the bottom of stair is 80 feet at which point there are two directions of egress travel available
  • Mezzanine grows and becomes a second floor
    Given: A nonsprinkled office space with an upper level mezzanine would like to expand the mezzanine into an adjacent tenant space But then the area of the mezzanine will exceed the allowable ratio when compared to the open and unobstructed area below Therefore the upper level will become a
  • Multi Story area with Stacked Mezzanines | Building Code Forum . . .
    In my opinion, the area on the left is a single-story space with four mezzanines, with the one mezzanine on the right having direct egress to the second story Just FYI, the total area of all mezzanines in the room on the left cannot exceed 1 3 the floor area of the room in which they are located